Guide
C1, C2, C3 and FI: reading the codes on your EICR
Four codes decide whether your report passes. What each one means, which ones fail the report, and what the 28-day clock asks of you.
EICR Coventry

On this page
Every observation on an Electrical Installation Condition Report carries a code. The overall result, satisfactory or unsatisfactory, follows directly from those codes, so it pays to know what each one means before the report lands.
The four codes
- C1, danger present. Someone could be hurt now, for example where live parts are exposed at a broken socket. The inspector should make it safe on the spot.
- C2, potentially dangerous. Not dangerous today, but it would become so with a fault or over time, such as missing main bonding to the gas or water pipes.
- FI, further investigation. Something couldn’t be confirmed during the inspection and may hide a C1 or C2, such as a circuit that couldn’t be traced.
- C3, improvement recommended. It doesn’t meet the current edition of BS 7671, but it isn’t unsafe.
Satisfactory or unsatisfactory?
Any C1, C2 or FI makes the whole report unsatisfactory. A report with only C3 observations can still be satisfactory.
What you have to do next
For C1, C2 and FI items, the work has to be finished within 28 days, or sooner if the report says. Then confirm it in writing to your tenant and the council within 28 days of finishing. You can use any qualified electrician for the repairs.
Need an EICR in Coventry?
Fixed price in writing before we book, PDF report within 48 hours.
Previous
Next