Landlord EICRsin Coventry,by the book
An Electrical Installation Condition Report for your rental, tested to BS 7671 by a qualified inspector. Fixed price in writing from £95, a PDF report within 48 hours, and we arrange access with your tenants.
| Circuit | IR MΩ | Zs Ω | RCD ms | Result |
|---|---|---|---|---|
| 1Lights, ground floor | >200 | 0.84 | 23 | Pass |
| 2Lights, first floor | >200 | 0.97 | 23 | Pass |
| 3Sockets, ring 1 | >200 | 0.52 | 23 | Pass |
| 4Sockets, ring 2 | >200 | 0.61 | 26 | Pass |
| 5Cooker | >200 | 0.38 | 26 | Pass |
| 6Shower | 180 | 0.31 | 26 | Pass |
IR: insulation resistance. Zs: earth fault loop impedance. RCD: trip time. Your report records every circuit like this, with any codes and an overall verdict.
What you get when you book
Every Coventry EICR we book works the same way, whether it’s a one-bed flat by the ring road or a seven-room HMO in Earlsdon.
An Electrical Installation Condition Report is a health check of the fixed wiring in your rental. It tells you, your tenants and the council whether the electrics are safe to keep using, and lists anything that needs fixing.
Before the visit
- A fixed price, in writingYou know the cost before you book: from £95 for a studio flat, and that’s what you pay for the report.
- We sort out accessWe agree a time with your tenants, so you don’t need to be there or pass messages back and forth.
- Anywhere in CoventryFlats, houses and HMOs across CV1 to CV6.
On the day
- A qualified inspectorCity & Guilds 2391, photo ID and a calibrated tester. Ask for their scheme number and check it on the scheme’s public register.
- Every circuit checkedThe consumer unit, wiring, sockets, switches, lights and earthing, tested against BS 7671, the national wiring standard.
- Short power cuts onlyThe power goes off in short spells while circuits are tested. We tell your tenants beforehand.
After the visit
- Your report within 48 hoursA PDF you can forward straight to tenants, your letting agent or the council.
- Repairs only if neededAnything that falls short gets an itemised quote. Use us or any qualified electrician, with no pressure.
- A reminder before the next oneAt least every five years, or sooner if the report says. We’ll remind you before it’s due.
Studio £95 · 1–3 bed £118.99 · 4 bed £129.99 · 5–8 bed £169.99–£219.99 · extra consumer unit £89.99
What the inspector brings, and what they test
Select a toolEach one has a painted outline, so nothing leaves the board without being noticed.
Multifunction testerCalibrated. Measures continuity, insulation resistance, earth fault loop impedance and RCD trip times. Ask to see the calibration date.
Test leads and probesFused leads with shrouded tips, in line with HSE guidance GS38, so a slip can’t cause a flash.
Two-pole voltage indicatorProves a circuit is dead before anything is touched.
Proving unitChecks the voltage indicator works before and after use: prove, test, prove.
Insulated screwdriversRated to 1000 V, for taking covers off and checking terminations.
TorchFor lofts, under-stairs cupboards and meter boxes, where most boards in Coventry terraces live.
Lock-off kitPadlocks and tags so nobody can switch a circuit back on while it’s being tested.
TabletRecords readings and observations as the inspector goes, ready for the report.
What every inspector we send holds: City & Guilds 2391 (inspection and testing), a working knowledge of BS 7671, photo ID, and a calibrated multifunction tester. Ask for their scheme registration number and check it on that scheme’s public register before the visit.
An EICR is a mix of looking and measuring. The inspector opens the board and samples accessories, then tests circuits with the power off and on.
- VisualBoard condition, cable routes, damaged sockets and switches, signs of heat, bathroom zones, outbuildings.
- ContinuityProtective conductors and ring circuits are unbroken from end to end.
- InsulationInsulation resistance between conductors, to catch damaged or ageing cable.
- PolaritySwitches and fuses are in the line conductor, not the neutral.
- Earth loopEarth fault loop impedance, so a breaker will clear a fault fast enough.
- RCDEach RCD trips within the required time.
- CodingEvery shortfall gets C1, C2, C3 or FI and the report gets an overall verdict.
The maintenance schedule the law sets
The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 (S.I. 2020/312), as amended by S.I. 2025/1043, apply to every Coventry let. Read the table like a service schedule: each dot is a deadline.
| Duty (regulation) | Before move-in | 7 days | 28 days | 5 years | Keep |
|---|---|---|---|---|---|
| Inspect and test the installation: first before the tenancy starts, then at least every 5 yearsreg 3(1)(b)–(c), 3(2) | yes | yes | |||
| Give the report to an existing tenantreg 3(3)(b) | yes | ||||
| Give a copy to a new tenant before they move inreg 3(3)(e)(i) | yes | ||||
| Copy to a prospective tenant who asks in writingreg 3(3)(e)(ii) | yes | ||||
| Copy to Coventry City Council if it asks in writingreg 3(3)(c) | yes | ||||
| Finish remedial or further investigation work (or sooner if the report says)reg 3(4) | yes | ||||
| Confirm the finished work in writing to the tenant and the councilreg 3(5) | yes | ||||
| Keep the report and give a copy to the next inspectorreg 3(3)(ca), (d) | yes |
Warning
The most a council can fine for each breach, up from £30,000 under S.I. 2025/1043 (in force for all purposes from 1 May 2026).
Tenant won't let you in?
Keep a record of every attempt to arrange access: dates, messages, letters. The regulations give you a defence where you took all reasonable steps, and not taking a tenant to court doesn’t on its own count against you (reg 3(2A)–(2B)).
We send the tenant the visit times for you, which helps build that record.
Coming next
Renters’ Rights Act 2025: periodic tenancies took effect on 1 May 2026. A private rented sector database is expected from late 2026, region by region; it isn’t in force yet.
Questions? 020 3386 1854
Coventry licensing, worked out on a chart
Since 4 May 2025 every HMO in Coventry with three or more people from two or more households needs a licence, across all 18 wards.
The additional licensing scheme covers HMOs with 3 or 4 occupiers, however many storeys. Five or more need the mandatory licence.
As of October 2026 there is no selective licensing for single-household lets in Coventry. The council has been looking at one, so check before you let.
Answer the questions
Pick how many people live there and how many households they form. The chart lights the route as you go.
Nearly there
Now pick whether they are one household (a family or couple) or two or more unrelated sharers.
No HMO licence
Coventry has no selective licensing scheme in force (October 2026), so a single-household let doesn’t need a licence. The council has been exploring one, so check before each new tenancy.
Your EICR duties apply either way: inspected before the tenancy starts, then at least every 5 years.
Additional HMO licence
Coventry’s additional licensing scheme covers every HMO with 3 or 4 occupiers, however many storeys, from 4 May 2025 to 3 May 2030.
The council asks for:
- A satisfactory EICR (or Electrical Installation Certificate), every page
- Gas safety certificate
- Fire alarm test certificate
- Emergency lighting test certificate, if fitted
- EPC
- PAT certificate for appliances you supply that are over a year old
- Photo ID for the licence holder
Mandatory HMO licence
Five or more people forming two or more households need a mandatory HMO licence anywhere in England, Coventry included.
The council asks for:
- A satisfactory EICR (or Electrical Installation Certificate), every page
- Gas safety certificate
- Fire alarm test certificate
- Emergency lighting test certificate, if fitted
- EPC
- PAT certificate for appliances you supply that are over a year old
- Photo ID for the licence holder
Converted block of flats
Coventry’s additional scheme also covers section 257 HMOs (blocks converted into flats that don’t meet the 1991 Building Regulations) when they are mainly or wholly let. Two exclusions: buildings of just 2 flats with no commercial premises above or below, and buildings where the flats share no common parts. These rules are technical, so check with the council’s HMO team.
Each flat still needs its own EICR. The communal installation (stair lighting, door entry, the fire alarm supply) is usually inspected too.
This ward is in the Article 4 area. Since 30 September 2023, turning a family home into a 3–6 person HMO here needs planning permission. HMOs already lawfully in use before then don’t need to apply; the licence application asks for proof of lawful use.
Need the EICR for the pack? 020 3386 1854
Source: Coventry City Council HMO licensing pages, checked October 2026. Council HMO team: 024 7697 5467.
Fig. 2 · Licence diagnostic. Source: Coventry City Council HMO licensing pages, checked October 2026.
The parts list for a Coventry HMO licence
The council’s licensing team asks for these papers with every mandatory and additional licence application. Pull a drawer to see what each one has to show.
EICR
A current, valid electrical safety certificate: an Electrical Installation Certificate or a periodic inspection report (EICR). Send the whole document, every page. Unsatisfactory reports are refused: the remedial work has to be done and a new satisfactory certificate sent.
Where we come in: We send the full report as a PDF within 48 hours, with an itemised quote for anything that needs fixing first.
Gas safety certificate
A current, valid gas safety certificate for every gas appliance, flue and the pipework, from a Gas Safe registered engineer.
Fire alarm test certificate
A current, valid fire alarm test certificate. Where the system is Grade D interlinked detection, the council accepts its self-certification form instead of an electrician’s certificate.
Emergency lighting
If the property has emergency lighting, a current test certificate. The council also accepts its self-certification form in place of an electrician’s certificate.
Energy Performance Certificate
A valid EPC for the property.
PAT certificate
A PAT certificate for any electrical equipment you supply to the tenants that is more than a year old: kettles, microwaves, fridges, lamps and so on.
Photo ID
If the licence holder is a person: a valid passport or driving licence (full or provisional).
Proof of planning use
In an Article 4 area: evidence that the property is lawfully in use as a C4 HMO, such as a previous HMO licence, a Lawful Development Certificate or a planning decision notice.
Coventry City Council, HMO licensing: licensing process. Licence conditions also ask you to send updated certificates as they expire.
Coventry's houses, by model year
Watchmaking, ribbon weaving, then bicycles and cars: each boom left its own streets, and each era of house wiring tends to show its age in its own way.
Victorian and Edwardian terraces
Earlsdon · Chapelfields · Stoke · Foleshill · Hillfields · Radford
Coventry grew fast on watchmaking and ribbon weaving, then bicycles. Chapelfields still has the long top-floor workshop windows of its 19th-century watchmakers. Most of these houses have been rewired at least once, often in stages.
What inspectors often look at
- Circuits extended over decades, by different hands
- Older boards without RCD protection on the sockets
- Earthing and main bonding to the gas and water pipes
- Rear extensions, cellars and lean-tos wired later
- Loft conversions with their own circuits
1920s–30s semis
Coundon · Cheylesmore · Styvechale · Wyken · Radford
As the car and aircraft works grew, the city spread outwards in bay-fronted semis. Many have had kitchens, extensions and garages added since, each with its own wiring.
What inspectors often look at
- Supplies run out to garages and sheds
- Kitchen and bathroom extensions
- Outside sockets without RCD protection
- Consumer units replaced but old circuits kept
Post-war rebuild
Tile Hill · Canley · Willenhall · Bell Green · Wood End
After the Blitz of 14 November 1940 the city centre was rebuilt as Britain’s first pedestrian precinct, and new estates followed on the edges of the city: low-rise blocks, maisonettes and plain brick houses.
What inspectors often look at
- Wiring from the 1960s and 70s that has never been fully replaced
- Storage-heater and off-peak circuits
- Landlord supplies in blocks: stair lighting, door entry
- Meter cupboards on shared landings
City-centre apartments
Inside and just outside the ring road · Friargate · office conversions
Purpose-built blocks and converted offices around the ring road. Most are all-electric, with heating and hot water on the same board as everything else.
What inspectors often look at
- Heavy electric heating and water-heating circuits
- The flat’s own board versus the landlord’s supply cupboard
- Communal fire alarm systems belong to the building, not your EICR
- Fobs and keys for locked meter rooms
Student HMOs
Near Coventry University (CV1) and the University of Warwick (CV4)
Shared houses in Earlsdon, Canley, Tile Hill, Stoke and Hillfields. More people means more appliances on the same circuits, and the licence brings its own paperwork.
What inspectors often look at
- Kitchen circuits carrying several people’s appliances
- The supply to the fire alarm and interlinked detectors
- Emergency lighting, where fitted
- Every bedroom has to be accessible on the day
- Updated certificates go to the council as they expire
Coventry runs on a ring
Fig. 3 · The ring road drawn as a ring final circuit, junctions as sockets. Not to scale.
The ring road loops the city centre through nine junctions, a lot like the ring final circuit that feeds your sockets. Pick a district, or type a postcode.
- Type a postcode, e.g. CV5 6AA.
- {d} is in Coventry. Details below.
- {d} is outside the city (Kenilworth, Bedworth, Warwick and around). Call 020 3386 1854 and we’ll tell you if we can book it.
- That doesn’t look like a Coventry postcode. This page covers CV1 to CV6.
CV1
Areas: City centre · Hillfields · Spon End · Gosford Green
Wards (approx.): St Michael’s (A4)
Inside and just outside the ring road: city-centre flats, student blocks near Coventry University and the Victorian streets of Hillfields and Spon End. Expect locked meter cupboards: send keys or a fob with the booking.
CV2
Areas: Stoke · Ball Hill · Wyken · Walsgrave · Bell Green · Wood End
Wards (approx.): Upper Stoke (A4) · Lower Stoke (A4) · Wyken · Henley · Longford
Terraces around Stoke and Ball Hill give way to 1930s semis in Wyken and post-war estates at Bell Green and Wood End.
CV3
Areas: Cheylesmore · Styvechale · Whitley · Willenhall · Binley · Finham
Wards (approx.): Cheylesmore (A4) · Wainbody (A4) · Binley and Willenhall · Lower Stoke (A4)
Inter-war semis in Cheylesmore and Styvechale, the post-war Willenhall estate and newer homes towards Finham.
CV4
Areas: Canley · Tile Hill · Westwood Heath · Cannon Park · University of Warwick
Wards (approx.): Westwood (A4) · Wainbody (A4) · Woodlands
Post-war Canley and Tile Hill, plus a lot of shared houses let to University of Warwick students.
CV5
Areas: Earlsdon · Chapelfields · Whoberley · Allesley · Allesley Park · Eastern Green
Wards (approx.): Earlsdon (A4) · Whoberley (A4) · Sherbourne (A4) · Bablake
Victorian and Edwardian terraces in Earlsdon, the watchmakers’ houses of Chapelfields, then semis and newer estates out to Allesley and Eastern Green.
CV6
Areas: Foleshill · Radford · Coundon · Holbrooks · Longford · Keresley · Edgwick
Wards (approx.): Foleshill (A4) · Radford (A4) · Sherbourne (A4) · Holbrook · Longford · Bablake
Long terraced streets off Foleshill Road and in Radford, inter-war semis in Coundon, and more modern homes out towards Keresley.
- Bablake
- Binley and Willenhall
- Cheylesmore A4
- Earlsdon A4
- Foleshill A4
- Henley
- Holbrook
- Longford
- Lower Stoke A4
- Radford A4
- St Michael’s A4
- Sherbourne A4
- Upper Stoke A4
- Wainbody A4
- Westwood A4
- Whoberley A4
- Woodlands
- Wyken
A4 = ward inside Coventry’s Article 4 direction (since 30 September 2023): turning a family home into a 3–6 person HMO needs planning permission. Ward boundaries don’t follow postcodes exactly.
Price list
Stamped on the plate before we book. These are our real Coventry prices for a full EICR.
Studio
- Full EICR to BS 7671
- PDF within 48 hours
- Fixed in writing
1–3 bed
- Full EICR to BS 7671
- PDF within 48 hours
- Fixed in writing
4 bed
- Extra consumer unit £89.99
- PDF within 48 hours
- Fixed in writing
5–8 bed
- 5 bed £169.99 · 6 bed £169.99
- 7 bed £199.99 · 8 bed £219.99
- HMOs: same bedroom scale
- Ready for the licence pack
- Inspection and testing of every circuit
- Each observation coded and explained
- PDF report within 48 hours
- Visit times arranged with your tenants
- Itemised repair quote, no pressure
- Reminder before the next one is due
Not sure which plate fits? Tell us the bedrooms and boards and we’ll fix the price in writing. Each extra consumer unit is £89.99.
Price gauge
Turn the knob to your bedrooms and flick the switches. The needle shows the band from our price list.
The final price is fixed in writing before we book, so there are no surprises on the day.
Each extra consumer unit adds £89.99. We’ll confirm the total in writing before we book.
Five to eight bedrooms run from £169.99 to £219.99. We’ll confirm it in writing before we book.
HMOs are priced on the same bedroom scale, plus £89.99 for each extra consumer unit. Call and we’ll fix it in writing.
- fixed in writing before we book
- HMO · same bedroom scale
Down the line: how a visit runs
Coventry built cars on moving lines. Your EICR runs the same way, station to station, and you can stop the line at any point to read the detail.
Call: Fixed price first
Ring 020 3386 1854 or send the order card. Tell us the address, bedrooms, boards and whether it’s an HMO, and you get a fixed price in writing before anything is booked.
Access: Tenants sorted
We contact your tenants with visit times and confirm them in writing, so you don’t need to be there. Power goes off for parts of the test, and we tell them that in advance.
Testing: On the day
The inspector checks the board, samples accessories and tests every circuit with the power off and on. A small flat usually takes a few hours; a large HMO takes longer.
Report: Within 48 hours
You get the EICR as a PDF within 48 hours, every observation coded and explained in plain English, ready for your tenants and the council.
Repairs: Your choice
If anything is coded C1, C2 or FI you get an itemised quote. Use us or any qualified electrician; the deadline is 28 days, or less if the report says.
Reminder: Before it’s due
We note the next due date and remind you before it comes round, so the five-year cycle never slips.
Fault-finding chart: reading the codes
Every observation on an EICR carries a code. Any C1, C2 or FI makes the whole report unsatisfactory, and the 28-day clock starts.
Danger present
Someone could be hurt now. The inspector should make it safe on the spot, for example by isolating the circuit.
DeadlineMake safe straight away, then confirm the repair in writing within 28 days.
Typical findings
- Live parts exposed at a broken socket
- Signs of arcing or burning at the board
Potentially dangerous
Not dangerous today, but would become so with a fault or over time.
DeadlinePut right within 28 days, or sooner if the report says.
Typical findings
- No main bonding to the gas or water pipes
- No RCD on sockets likely to feed outdoor equipment
Further investigation
Something couldn’t be confirmed during the inspection and may hide a C1 or C2.
DeadlineInvestigate within 28 days and act on what’s found.
Typical findings
- A circuit the inspector couldn’t trace
- Low insulation readings with no visible cause
Improvement recommended
Doesn’t meet the current edition of BS 7671, but isn’t unsafe.
DeadlineNo legal deadline. Worth planning in with other work.
Typical findings
- No circuit chart at the consumer unit
- Older board without surge protection
Pick something you’ve noticed at the property.
- A broken socket with live parts showing
- No main bonding to the gas or water pipes
- Scorch marks or heat damage at a socket or the board
- Sockets that could feed outdoor equipment have no RCD
- A circuit the inspector couldn’t trace
- No circuit chart at the consumer unit
Danger present
Anyone could touch a live part. The inspector should isolate it or make it safe there and then, with your permission.
- Report
- Unsatisfactory
- Your duty
- Finish the work within 28 days (or sooner if the report says), then confirm it in writing to the tenant and the council.
Potentially dangerous
Main protective bonding stops metal pipework becoming live during a fault. Its absence is usually coded C2.
- Report
- Unsatisfactory
- Your duty
- Finish the work within 28 days (or sooner if the report says), then confirm it in writing to the tenant and the council.
Potentially dangerous
Overheating usually points to a loose connection or an overloaded accessory. Typically C2, or C1 if there’s immediate danger.
- Report
- Unsatisfactory
- Your duty
- Finish the work within 28 days (or sooner if the report says), then confirm it in writing to the tenant and the council.
Potentially dangerous
An RCD cuts the supply when current leaks to earth, for example through a person. For sockets likely to power equipment outdoors, its absence is typically C2.
- Report
- Unsatisfactory
- Your duty
- Finish the work within 28 days (or sooner if the report says), then confirm it in writing to the tenant and the council.
Further investigation
If a circuit can’t be traced or tested, for example because cables disappear into a sealed void, the inspector can’t confirm it’s safe.
- Report
- Unsatisfactory
- Your duty
- Finish the work within 28 days (or sooner if the report says), then confirm it in writing to the tenant and the council.
Improvement recommended
Missing labels make isolation harder for the next electrician but aren’t dangerous in themselves, so this is usually an improvement.
- Report
- Can still be satisfactory
- Your duty
- None by law, but worth planning in.
Typical outcomes based on industry best-practice guidance. The inspector decides each code on site.
Service record: when is the next one due?
Enter the date on your last report. The inspector may have set a shorter interval than five years, so check the “next inspection” box on page one.
We’ll keep this date on file once you book, and remind you before it comes round.
Service record
| Last inspection | |
|---|---|
| Next due by | |
| Book the visit from | |
| Time left |
- This report is past its date. Book an inspection now: 020 3386 1854.
- Inside the booking window. Call 020 3386 1854 to fix a date before {due}.
- You’re covered for now. Book from {from} so there’s time for any remedials.
- As a licensed HMO, send the new certificate to Coventry City Council when it’s issued.
Student lets: test in the summer gap
Coventry University’s campus sits inside the ring road and the University of Warwick is on the city’s south-west edge in CV4, so a lot of shared houses turn over in the same few weeks each year.
Book in the gap
When a house sits empty between tenancies, the inspector can switch circuits off without working around anyone, and any remedial work is done before the new group moves in.
Licence conditions
Shared houses with three or more students from different households are licensable HMOs here. Coventry’s licence conditions ask you to send updated certificates to the council as they expire, so diarise the EICR along with gas and fire alarm.
Article 4 streets
Earlsdon, St Michael’s, Radford, Lower and Upper Stoke and six other wards need planning permission to turn a family home into a new HMO. Existing lawful HMOs carry on.
Before the inspector arrives
Under-stairs cupboards fill up. The inspector needs room to take the cover off.
Fobs, padlock codes and the landlord’s cupboard in blocks of flats.
We send times, but a note from you helps. Fridges and freezers are fine if they stay shut.
Medical equipment, fish tanks, home servers: tell us and we’ll plan around them.
In HMOs, locked bedrooms mean untested sockets and a limitation written on the report.
Sheds, garages and garden sockets are part of the installation.
Old EICRs and certificates for rewires or new circuits help the inspector.
A breaker that trips, lights that flicker, a warm socket: mention it on arrival.
Tick each item as you sort it. Nothing here is compulsory, but each one makes the visit smoother.
All set. The inspector can get straight to work.
Questions before the day? 020 3386 1854
Index of questions
What Coventry landlords ask us most before booking. Something else? Call 020 3386 1854.
How much does an EICR cost in Coventry?
A studio flat is £95, a one to three-bed home £118.99 and a four-bed home £129.99. Five to eight-bed homes are £169.99 to £219.99, HMOs are priced on the same bedroom scale, and each extra consumer unit is £89.99. The exact price is fixed in writing before we book.
How often does a Coventry rental need an EICR?
At least every five years, or sooner if the last report says so. The first inspection has to be done before a tenancy starts. If the property is a licensed HMO, your licence conditions also ask you to send updated certificates to the council as they expire.
Does my Coventry HMO need a licence?
If three or more people from two or more households live there, yes. Coventry’s additional licensing scheme covers HMOs with 3 or 4 occupiers across the whole city from 4 May 2025 to 3 May 2030, and HMOs with 5 or more need a mandatory licence. Some converted blocks of flats (section 257 HMOs) are covered too.
Will the council accept an unsatisfactory EICR with my licence application?
No. Coventry City Council says unsatisfactory certificates are not accepted: the remedial work has to be done and a new satisfactory certificate sent in. Send every page of the report, not just the first.
Is there selective licensing in Coventry?
Not as of October 2026. The council has been exploring selective licensing for parts of the city, so check its website before a new let. Your EICR duties apply whether or not a licence is needed.
How long does the inspection take?
It depends on the number of circuits and boards. A small flat usually takes a few hours; a large house or HMO takes longer. We’ll give you an idea when you book.
Do I need to be there?
No. We agree visit times with your tenants and confirm them in writing. If the property is empty, we can collect keys from you or your agent.
Will the power be off?
For parts of the test, yes, circuit by circuit. We tell tenants beforehand. Fridges and freezers are fine if they stay shut; tell us about anything that must stay on, such as medical equipment.
What happens if my report is unsatisfactory?
You have 28 days (or less if the report says) to do the remedial or investigation work, then confirm it in writing to your tenant and the council within 28 days of finishing. We send an itemised quote, and you can use any qualified electrician.
What's the difference between an EICR and PAT testing?
An EICR covers the fixed wiring: board, circuits, sockets, switches and lights. PAT testing covers plug-in appliances. Coventry’s HMO licence application asks for a PAT certificate for any appliances you supply that are over a year old.
Do you cover Kenilworth, Bedworth or Balsall Common?
This page is for Coventry itself, CV1 to CV6. For addresses just outside the city, call 020 3386 1854 and we’ll tell you straight away whether we can book it.
I live in my Coventry home. Do I need an EICR?
It isn’t a legal requirement for owner-occupiers. The IET recommends an inspection every 10 years or when a home changes hands, and many buyers ask for one.
Get your fixed price
No obligation. We reply with the price in writing, or call 020 3386 1854.
What happens next
- We confirm your priceIn writing, based on the property you’ve described. That’s what you pay for the report.
- We book a timeWe agree it with you or directly with your tenants.
- The inspectionA qualified inspector tests every circuit against BS 7671.
- Your report within 48 hoursA PDF ready to send to tenants and the council, plus an itemised quote if anything needs fixing.